Publish Time: 2023-01-10 Origin: Site
Faults:
The motor does not work after energizing, and there is no abnormal sound, odor and smoke.
Check the fault cause:
1. Whether the power line is connected or not.
2. Whether the insurance system burns out.
3. Whether the current/voltage is adjusted too small.
4. Whether the equipment connection is wrong.
After checking the cause of the fault and then troubleshooting:
1. Check the power line, fuse and wiring for any broken wires and repair them.
2. If the fuse is burnt out, check the model and the cause of the fuse and replace it.
3. adjust the voltage and current fixed value, consistent with the motor.
4. Check the wiring connection and make it correct.